BlueHat Mechanical has been servicing the heating, air conditioning and refrigeration needs of businesses in Raleigh NC for the past 14 years. Call us now at: 919-773-9223 or check out our reviews from companies in Raleigh NC.

Local Reviews
for Raleigh, NC

BlueHat Mechanical Rated 4.9 out of 5 stars based on 281 customer reviews


Great service




Review of BlueHat Mechanical

It’s okay awesome


Great service / Very thorough




Review of BlueHat Mechanical

Technician was very knowledgeable and friendly.


Tech was very professional and knew what to do




Review of BlueHat Mechanical


Great Service very knowledgeable




Review of BlueHat Mechanical

Great all around!


Excellent as Always!




Review of BlueHat Mechanical

Blue Hat is always super responsive & work is completed quickly and efficiently.


Chief Engineer




Review of BlueHat Mechanical


Chief Engineer




Review of BlueHat Mechanical


Helped me out




Review of BlueHat Mechanical

I had a Gas hot water heater go out on me overnight. Tom came in and helped get the gas side working again which got us Hot water before we got to our busy time. I am thankful for his work because you guys got us hot water even though yall don't service them.


Tommy was very professional




Review of BlueHat Mechanical


Great tech, very knowledgeable




Review of BlueHat Mechanical


Chief Engineer




Review of BlueHat Mechanical


Chief Engineer




Review of BlueHat Mechanical


Friendly and knowledgeable staff




Review of BlueHat Mechanical


Chief Engineer




Review of BlueHat Mechanical


Great Job




Review of BlueHat Mechanical

Curtis was on time and very courteous!


Great service




Review of BlueHat Mechanical


Amazballs!




Review of BlueHat Mechanical


Great service




Review of BlueHat Mechanical


Chief Engineer




Review of BlueHat Mechanical


Great customer service, timely follow up




Review of BlueHat Mechanical


Great service




Review of BlueHat Mechanical


Chief Engineer




Review of BlueHat Mechanical


Awesome




Review of BlueHat Mechanical

I always thought JD was the best, then we got Tony , wow no comparison


Great service




Review of BlueHat Mechanical


David, was very professional.




Review of BlueHat Mechanical

David was knowledgeable about the equipment he was working on, also very courteous, a real pleasure to work with


Chad B.

Chad B.

Suggested for Back of building in ceiling BHM08795 AHU Heil FEM4X6000BL F193312628: BHM08795-Completed full cooling pm of ahu 2 (rear above water fountains). Due to lack of water source I could not fully clean evaporator. I used 1 can of no rinse evap cleaner. The coil looked fairly clean. Took slightly longer than expected due to water line and work station in the way. I thoroughly flushed the condensate drain line with co2 and then vacuumed out. No obstruction to note at this time. Fan motor running normally. No sign of water (neither past or present) in drain pan. Put the panels back on then started unit back up. Unit is running normally and condensation is normal. Replaced return air grille filter and fresh air filter. The fresh air filter showed minimal wear. Could be because unit is getting proper amount of fresh air. No visible damper. Will ne to investigate further to find cause. *customer stated after being set to 80° during quarantine period when they returned there were 7

Near Harvest Oaks Dr, Raleigh, NC 27615
Curtis B.

Curtis B.

Near Ajinomoto Dr, Raleigh, NC 27610
Bryce L.

Bryce L.

Troubleshoot and Repair HVAC Unit

Near Louisburg Rd, Raleigh, NC 27604
Chad B.

Chad B.

Suggested for Back of building in ceiling BHM08795 AHU Heil FEM4X6000BL F193312628: BHM08795-Completed full cooling pm of ahu 2 (rear above water fountains). Due to lack of water source I could not fully clean evaporator. I used 1 can of no rinse evap cleaner. The coil looked fairly clean. Took slightly longer than expected due to water line and work station in the way. I thoroughly flushed the condensate drain line with co2 and then vacuumed out. No obstruction to note at this time. Fan motor running normally. No sign of water (neither past or present) in drain pan. Put the panels back on then started unit back up. Unit is running normally and condensation is normal. Replaced return air grille filter and fresh air filter. The fresh air filter showed minimal wear. Could be because unit is getting proper amount of fresh air. No visible damper. Will ne to investigate further to find cause. *customer stated after being set to 80° during quarantine period when they returned there were 7

Near Harvest Oaks Dr, Raleigh, NC 27615
Curtis B.

Curtis B.

Replace Blower Sheave

Near 4301 Louisburg Road, Raleigh, NC 27604
David L.

David L.

Refrigeration Emergency Service Call

Near W Jones St, Raleigh, NC 27603
David L.

David L.

Troubleshoot and repair refrigeration equipment.

Near Tucker St, Raleigh, NC 27603
Bryce L.

Bryce L.

Troubleshoot and Repair HVAC Equipment

Near Wake Forest Rd, Raleigh, NC 27608
David L.

David L.

HVACR Service Call

Near Agriculture St, Raleigh, NC 27603
David L.

David L.

Troubleshoot and repair line coolers.

Near W Jones St, Raleigh, NC 27603
David L.

David L.

Troubleshoot and repair line coolers.

Near W Jones St, Raleigh, NC 27603
David L.

David L.

HVACR and HVAC Service Call

Near Midway West Rd, Raleigh, NC 27617
Matt P.

Matt P.

Troubleshoot and Repair Chiller

Near Midway West Rd, Raleigh, NC 27617
David L.

David L.

HVACR Service Call

Near W Davie St, Raleigh, NC 27601
Chad B.

Chad B.

Perform Planned Maintenance on HVAC and Refrigeration Equipment Suggested for Left most walk-in BHM05896 Whitt (Heat Transfer Products Group) GLD400L44-E E16G00761867003001: Completed full refrigeration pm per tasking list. Chemically cleaned condenser coil Inspected electrical components Verified defrost clock working normally. Verified operation Returned to service No issues to note at this time Suggested for Center "Beer Cave" walk-in BHM05899 Whitt (Heat Transfer Products Group GLD500M44-E E16G007618670010: Completed full refrigeration pm per tasking list. Chemically cleaned condenser coil Inspected electrical components Verified defrost clock working normally. Verified operation Returned to service No issues to note at this time Suggested for Right most cooler BHM05895 Whitt (Heat Transfer Products Group WFH325E44-EA E16F00756935001001: Completed full refrigeration pm per tasking list. Chemically cleaned condenser coil Inspected electrical components Verified defrost cl

Near Glenwood Ave, Raleigh, NC 27603
David L.

David L.

Perform Planned Maintenance on Ice Machines

Near Dixon Dr, Raleigh, NC 27609
Matt P.

Matt P.

Replace Capacitor

Near Ray Rd, Raleigh, NC 27613
David L.

David L.

Perform Planned Maintenance on Ice Machines

Near Dixon Dr, Raleigh, NC 27609
David L.

David L.

Troubleshoot Reach In Cooler

Near Park at N Hills St, Raleigh, NC 27609
David L.

David L.

Troubleshoot and Repair Ice Machine

Near Oberlin Rd, Raleigh, NC 27608
David L.

David L.

Perform Planned Maintenance on Ice Machine

Near Dixon Dr, Raleigh, NC 27609
David L.

David L.

Planned Maintenance on Ice Machine

Near Strickland Rd, Raleigh, NC 27615
Curtis B.

Curtis B.

Perform Planned Maintenance on HVAC Equipment

Near Six Forks Rd, Raleigh, NC 27615
Curtis B.

Curtis B.

Troubleshoot and Repair HVAC Unit

Near Ajinomoto Dr, Raleigh, NC 27610
Chad B.

Chad B.

Inoperable Deficiency for Closet at front desk BHM05774 Heat pump - ele heat backup Carrier FB4ANA060 1092H09638 BHM05773: Customer called stating unit is blowing 80° air. I arrived and met with Tom. The unit was off and space temp 77. Once we turned the unit on it was blowing 83° at the registers. Verified evap coil clean and had good airflow. Air filter was newer. Went outside and the contractor was pulled in. Fan was blowing and rotating the correct way. I did notice the fan motor was leaking oil onto the blade shaft. The compressor was giving off a huge amount of heat. There was scorching on the paint on the compressor head. Gauges showed pressures even on high and low side. I ran a hose and sprayed coil and compressor with water to cool it down. I turned back on and the compressor wasn’t running. I turned it off and checked the resistance on the windings and it was open. This was causing compressor not to run. Showed customer and explained my findings. Due to age (1995 install d

Near Old Stage Rd, Raleigh, NC 27603