BlueHat Mechanical has been servicing the heating, air conditioning and refrigeration needs of businesses in Apex NC for the past 14 years. Call us now at: 919-773-9223 or check out our reviews from companies in Apex NC.

Local Reviews
for Apex, NC

BlueHat Mechanical Rated 4.9 out of 5 stars based on 70 customer reviews


.




Review of BlueHat Mechanical


Very nice Technicians




Review of BlueHat Mechanical

Technician was very nice and polite but having problems with getting our systems resolved


Outstanding service by a professional service tech




Review of BlueHat Mechanical

Chad was very knowledgeable and a pleasure to work with.


Very amazing job.




Review of BlueHat Mechanical


Very Professional!




Review of BlueHat Mechanical

Very thorough job, explained in detail the issue!


Clean coils




Review of BlueHat Mechanical


Preventive maintenance




Review of BlueHat Mechanical


What you should get!!!




Review of BlueHat Mechanical

Blue Hat and their staff were GREAT! Our technician was on-time, pleasant, knowledgable, and on task the entire time he was here servicing our machines. Scheduling was a breeze!


Quick response did job quickly




Review of BlueHat Mechanical


Preventive maintenance




Review of BlueHat Mechanical


Curtis B.

Curtis B.

Troubleshoot and Repair HVAC Unit

Near Reliance Ave, Apex, NC 27539
Bryce L.

Bryce L.

Perform Planned Maintenance on HVAC Equipment

Near Schieffelin Rd, Apex, NC 27502
Curtis B.

Curtis B.

Perform Planned Maintenance on HVAC Equipment

Near Production Dr, Apex, NC 27539
Chad B.

Chad B.

Inoperable Deficiency for Zone 3 condensing unit BHM09141 Split System Trane TWA073D30RAA 11113U2BYA: BHM09141 Call was for no cooling zone 3 Turned tstat on to call for cooling. Found unit on the roof was cooling but the compressor had a weird whirring sound every now and then. The compressor windings opened and the pressures equalized. The fan was still spinning. And the unit is still calling for cooling. The compressor came back on and I checked the amp draw. The ampdraw was fluctuating up and down from 27 to 38 amps. The RLA for the compressor is only 22 amps. The compressor has internal problems and needs to be replaced Suggested for Zone 3 condensing unit BHM09141 Split System Trane TWA073D30RAA 11113U2BYA: Arrived to replace compressor and filter drier on zone 3 rtu. This is a quoted job fro, previous visit. I arrived and checked in then went to the roof and pulled 17 pounds of r410a out of unit. I cut the discharge and suction lines. Then I remove the fan and top of unit

Near Reliance Ave, Apex, NC 27539
Curtis B.

Curtis B.

Replace Condenser Coil

Near Classic Rd, Apex, NC 27539
Curtis B.

Curtis B.

Replace Blower Motor

Near Hunter St, Apex, NC 27502
Bryce L.

Bryce L.

Troubleshoot and Repair HVAC Unit

Near Reliance Ave, Apex, NC 27539
Keith H.

Keith H.

Troubleshoot and Repair HVAC System

Near Hunter St, Apex, NC 27502
Curtis B.

Curtis B.

Perform Planned Maintenance on HVAC Equipment

Near N Salem St, Apex, NC 27502
Bryce L.

Bryce L.

Troubleshoot and Repair HVAC System

Near Investment Blvd, Apex, NC 27502
Bryce L.

Bryce L.

Troubleshoot and Repair HVAC Equipment

Near Classic Rd, Apex, NC 27539
Bryce L.

Bryce L.

Troubleshoot and Repair HVAC Equipment

Near Classic Rd, Apex, NC 27539
Curtis B.

Curtis B.

Troubleshoot and Repair Mini-Split

Near Lufkin Rd, Apex, NC 27539
Chad B.

Chad B.

Suggested for CU-1 BHM09256 Split System Trane 4TTR4036L1000AA 19232RA33F: Arrived to customer stating 3 offices in the back are 75°. I found the condensing unit 1 and AHU1 both running normally. Air temp at registers 70°. I verified there was no airflow issue across the coil due to dirt and/or debris and there isn’t. I found a supply run of duct became slightly separated from the register boot. I resecured and when outside and put gauges on. Pressures for 410a with 77° oddb were: 268 head / 120 suction. *picture attached* this gave me a subcool of 4°. At this point I added 1 lb of r-410a and this brought my pressures up to *picture attached*: 296psig head / 120 psig suction for a subcool of 12.5 within manufacturer recommended 10° /-3° After running for a few minutes I measured temp at registers and it is 50-52°. Nothing further at this time. No signs of a leak. * another issue is the thermostat is in back office and there currently no temp sensors for other

Near Investment Blvd, Apex, NC 27502
Matthew H.

Matthew H.

Near Silver Stirrup Ln, Apex, NC 27502
Curtis B.

Curtis B.

Troubleshoot and Repair HVAC Unit

Near Lufkin Rd, Apex, NC 27539
Chad B.

Chad B.

Suggested for ERV 2 Above ceiling midway on left side of building ERV 2 Energy recovery Renew Aire HE3XIN A19 17: Erv2 supply side: returned to complete blower change out via renew air warranty. I checked in with Larkin before starting. Once I started disassembling I noticed the blower assembly was bolted in from opposite side as well. The far side was proving to be challenging reach as I could not crawl between the top of the erv and the ceiling (roughly 6” clearance). After discussing options with JD we decided the best option at this point was to replace the bearings. We took bearings off new unit and put on old blower wheel. Once mounted the A42 belt was to tight and needed to be upsized. We had a A43 belt delivered and installed it. We properly aligned and tensioned the belt to manufacturer specs. Once completed we energized erv2 and verified operation. The new bearings operated smoothly. *followup: we noticed on the top blower for fresh air intake the pulley gap was signi

Near Investment Blvd, Apex, NC 27502
Matthew H.

Matthew H.

Near Silver Stirrup Ln, Apex, NC 27502
Matthew H.

Matthew H.

Perform Maintenance and Repair of Pool Heat Pump

Near Hazelhurst Cir, Apex, NC 27502
Bryce L.

Bryce L.

Troubleshoot and Repair Air Dryer

Near Classic Rd, Apex, NC 27539
Chad B.

Chad B.

Suggested for CU3 Left side of building BHM09122 Split System Trane 4TTR6030J1000AA 183338A45F: Completed full ac PM of CU-3. Inspected electrical components. Chemically cleaned condenser coil, verified operation, will have to return on a warmer day to return pressures and check superheat and subcool. Suggested for CU4 Left side of building BHM09123 Split System Trane 4TTR6030J1000AA 183345P85F: Completed full ac PM of CU-4. Inspected electrical components. Chemically cleaned condenser coil, verified operation, will have to return on a warmer day to return pressures and check superheat and subcool. Suggested for CU5 Right side of building BHM09124 Split System Trane 4TTR6042J1000AB 18451TX65F: Completed full ac PM of CU-5. Inspected electrical components. Chemically cleaned condenser coil, verified operation, will have to return on a warmer day to return pressures and check superheat and subcool. Suggested for CU1 Left side of building BHM09120 Split System Trane 4TTR6060J1000A

Near Investment Blvd, Apex, NC 27502
Bryce L.

Bryce L.

Perform Planned Maintenance on HVAC Equipment

Near Hunter St, Apex, NC 27502
Bryce L.

Bryce L.

Perform Planned Maintenance on HVAC Equipment

Near Hunter St, Apex, NC 27502
Bryce L.

Bryce L.

Perform Planned Maintenance on HVAC Equipment

Near Hunter St, Apex, NC 27502
Chad B.

Chad B.

HVAC Planned Maintenance Suggested for 2nd back from front BHM03536 Split Heat Pump Trane 2TWA0060A3000AB 7295UE21F: Completed full AC pm per tasking list. Chemically cleaned condenser coil, fan motor reading 1.4 rla, cleaned dirt and spider webs from electrical compartments, ran unit and checked pressures. 189 head/ 68 suction. Subcool reading 8.8 degrees. Suggested for Shop ceiling Bhm07295 Ahu Trane Bhm03639: Completed full AC pm per tasking list. Chemically cleaned condenser coil, fan motor reading 1.5 rla, cleaned dirt and spider webs from electrical compartments, ran unit and checked pressures. 186 head/ 68 suction. Subcool reading 8.8 degrees. Suggested for Back Gym BHM02242 Package Unit Trane 2TWA0048A3000AB 72536C14F: Completed full AC pm per tasking list. Chemically cleaned condenser coil, fan motor reading 1.5 rla, cleaned dirt and spider webs from electrical compartments, ran unit and checked pressures. 189 head/ 65 suction. Subcool reading 8.6 degrees. Suggested for S

Near Production Dr, Apex, NC 27539